MLH Pressure Transducer

TIG31065

US$247.07

Literature

Literature


Pressure transducer is only compatible with the Retarder Control Module (TRCM). This part cannot be used with Telma ABS Interface, or Telma Speed Switch.

Specifications

Specifications


MLH Pressure Transducer for use with TIG31062, Telma Control Module (TRCM) Output: 1 to 6 VDC Input: 8 to 30 VDC Pressure: 0 to 50 psi Max Pressure: 500 psi TRCM Configuration: 1 volt per 10 PSI Set Transducer voltage in TRCM software to get corresponding pressure (*pressures indicate suggested trigger pressures): Volts = PSI 1.00 = 0 1.10 = 1 1.20 = 2 1.30 = 3* 1.40 = 4 1.50 = 5* 1.60 = 6 1.70 = 7* 1.80 = 8 1.90 = 9* 2.00 = 10