MLH Pressure Transducer for use with TIG31062, Telma Control Module (TRCM)
Output: 1 to 6 VDC
Input: 8 to 30 VDC
Pressure: 0 to 50 psi
Max Pressure: 500 psi
TRCM Configuration:
1 volt per 10 PSI
Set Transducer voltage in TRCM software to get corresponding pressure (*pressures indicate suggested trigger pressures):
Volts = PSI
1.00 = 0
1.10 = 1
1.20 = 2
1.30 = 3*
1.40 = 4
1.50 = 5*
1.60 = 6
1.70 = 7*
1.80 = 8
1.90 = 9*
2.00 = 10